CB-600 Technical parameters:Two sets of output are equipped with two sets of spectrum jump indicators.Each channel corresponds to the input and output, the input uses a new multi-function socket, incl

  • Model: CB-600


MetInfo enterprise content manager system | MetInfo CMSMetInfo enterprise content manager system | MetInfo CMS

CB-600 Technical parameters:

Two sets of output are equipped with two sets of spectrum jump indicators.

Each channel corresponds to the input and output, the input uses a new multi-function socket, including (CANNON) XLR and RCA lotus connectors

Type: RF filter,servo-balanced input

Input  impedance:  40kΩ balance

Norminal operating:  40dB to -2dB

Maximum input : +20 dBu unbalance

OUTPUT

Type:  DC-decoupled balance output stage

Output impedance:  40Ω balance

Maximum output:  +20 dBu unbalance

Bandwidth:  10Hz-50kHz (+0.-dB)

Total harmonic distortion(+4 dBu):  0.005%

MONO BASS OUTPUT

Type:  DC-decoupled balance output stage

Output impedance : 40Ω balance

Maximum output : +20 dBu unbalance

Bandwidth : 10Hz 250Hz(+0,-1 dB)

Total harmonic distortion(+4 dBu) : 0.005%

LOW BAND PROCESSOR

Shift switch : change 50Hz or 100Hz

Low mix  :variable from off to max

HIGH BAND PROCESSOR

Turn:  variable from 1 kHz to 8kHz

Prosess  variable from classic (heavy) to pop (thin)

High mix:  variable from offto max

MONO LOW-FREQUENCY SIGNAL PROCESSOR

Phase switch : change 0° or 180°

Xover frequency:  variable from 100Hz to 250 Hz

Output : variable from-zto+ 12dB

POWER SUPPLY

Main voltage:  :AC 220V 50-60Hz

Power comsumption :10W